The Vision-R™ 700 fully-digital refraction system, complete with a console and chart screen, creates value for practices in raising their productivity and patient experience, going beyond what a traditional digital motorized refractor delivers.

  • Exclusive optical module permitting multiple incremental power changes to secure rapid 0.25D proven accuracy
  • Simultaneous lens changes for a more direct and controlled refraction method: Digital Infinite Refraction
  • Patient-specific program recommendation for guidance from start to finish
  • Smart programs for easy refractions by simply recording patient answers
  • Improved patient experience thanks to a wider field of vision, silent lens changes, and an easy response method
  • Instant power changes for easy comparisons and patient confidence
(NEW) Launch of Software v3.2 with Easy Refraction Mode

The new main software version 3.2 features advanced capabilities that enhance versatility of our instruments with additional speed and efficiency for eye care professionals and their teams:

  • Easy Refraction Mode™ for fully guided adaptive refraction sequences, allowing to share refraction care to all levels of expertise under the control of eye care professionals
  • Smart Addition program delivering assisted and quick near accommodation assessment to ease addition needs measurements and prescriptions
  • Multiroom refractor-to-refractor connectivity through CBOX and QR codes further enhances shared care application and digitalization of the patient journey

Note: Submitting a support ticket will take you to a separate website.

$32.00

ACCELERATE REFRACTION…WITHOUT COMPROMISING ON ACCURACY

A good refraction can take time, but more time can lead to less efficiency. Until now, the only way to shorten the traditional procedure of bracketing the sphere, cylinder and axis independently was by cutting crucial steps. This can result in bigger variances and an estimation of the prescription.

TAKE ADVANTAGE OF A BREAKTHROUGH IN REFRACTION TECHNOLOGY

Essilor developed an exclusive liquid-lens optical module that allows for a much smoother refraction process. This innovative technology incorporates a fast, multiple-increment algorithm to give you an exact refraction in a short period of time with a minimum increment of 0.12D adjustable to 0.12/0.25/0.50/1.00/2.00D. Furthermore, enhanced data communication with patient management systems makes for a seamless workflow across your practice.

1. FAST REFRACTION WITH SECURED ACCURACY

Outdated technology had eye care professionals believing that any increase in speed meant a decrease in accuracy. The Essilor Vision-R 700 refraction system breaks this compromise.

Thanks to Digital Infinite Refraction, Vision-R 700 obtains a fast refraction in only three minutes, while securing accuracy.

With dedicated Smart Programs and algorithms, Vision-R 700 controls accuracy by using small and large increments of the continuous lens.

How does the Vision-R 700 refraction system redefine refraction?

SMART PROGRAMS AND ALGORITHMS

A series of patient-specific Smart Programs incorporating Digital Infinite Refraction shorten the procedure and assist in calculating the best endpoint for the patient.

SIMULTANEOUS COMPENSATION

This innovation allows for a fast and direct refraction method: Digital Infinite Refraction. Continuous compensation on the sphere, cylinder and axis ensures accuracy, as answers are based on compensated powers, eliminating the need for estimated lens compensation.

CONTINUOUS LENS POWER

Smooth and instant transitions between multiple dioptric powers eliminate unwanted stimuli and control accommodation.

VERTEX DISTANCE MEASUREMENT

Vertex distance is measured to the millimeter and controllable from a distance. Combined with the automatic compensation to the reference vertex distance, accuracy is controlled right to the end.

2. EASY TO PERFORM

The Vision-R 700 refraction system has been developed with ease of use and performance excellence as its starting points. The process is designed to guide the practitioner from start to finish. The eye care professional (ECP) only needs to record data, while the refractor changes the dioptric values and relevant tests to achieve the final result.

What makes it easy to use with excellent results?

PROGRAM RECOMMENDATION FUNCTION

A Smart Program recommendation is made for each patient. Depending on the imported patient data, the ideal program is recommended by the refraction system.

SMART TESTS AND ALGORITHMS

Vision-R 700 comes with automated Smart Tests that assist the ECP when performing the refraction, making the refraction system truly user-friendly.

Algorithms change the tests and calculate the dioptric power in reaction to the patient’s answers.

SECURE PROCEDURE

The secure and guided procedure from start to finish ensures an accurate result, even in the hands of less experienced operators.

HELP FUNCTION

If needed, you can easily access a ‘Help’ function with details regarding the current test to help guide the ECP through the process.

3. IMPROVED PATIENT EXPERIENCE

The Vision-R 700 refraction system provides an excellent patient experience during refraction and eliminates the feeling of failing a test. Make the refraction experience remarkable through:

A COMPACT DESIGN AND SILENT LENS CHANGES

A modern design functions as a showcase for innovative technology. Its compact size makes it easier to handle. Its silent lens changes minimize distractions.

A WIDER FIELD OF VISION

No superposition of lenses as is needed in traditional phoropters. The patient has a more natural field of vision and is more comfortable without the effect of tunnel vision.

EASIER TO ANSWER

The patient now has the option to report that he sees “no difference” or “doesn’t know which option is better.” The Smart Tests use this information to give accurate results. The guessing game is eliminated and patient confidence reassured.

MULTIPLE COMPARISONS

An efficient and detailed comparison function, where multiple different scripts and scenarios can be compared at the click of a button. This allows the patient to imagine what to expect with the new prescription.

NO VISUAL FATIGUE

Thanks to the shorter process, the patient experiences less visual fatigue by providing fewer direct answers.

DISCOVER MANY OTHER FEATURES OF VISION-R 700

CUSTOMIZE

Full freedom to set up the refractor just the way you want it, from programming tests and programs to personalizing test charts and customizing the workflow.

REMOTE MAINTENANCE

Assistance in real time, whether it is for training, troubleshooting or upgrading.

CONNECTIVITY

The Vision-R 700 refraction system fits seamlessly into your practice. Data transfer between different connected devices is easy. Import to, and export from Vision-R 700 for a fully-streamlined workflow.

UPGRADABLE

The ability to upgrade the refractor with software to meet the latest needs makes Vision-R 700 innovative today and allows for improvements in the future.

AUTOMATIC NEAR-VISION CONTROL

Selecting the near-vision mode automatically changes to the near pupillary distance and activates the white LED near-vision illumination.

TOUCH SCREEN

10.4 inch, high-resolution adjustable touch screen with an ergonomic layout


DIGITAL INFINITE REFRACTION: A MORE DIRECT ACCESS TO THE FINAL PRESCRIPTION

DIGITAL INFINITE REFRACTION IN ONLY ONLY 2 STEPS

Thanks to the exclusive liquid-lens optical module, the new Digital Infinite Refraction process automatically compensates for the effect that any change in the sphere, cylinder and axis has on one of the other dimensions. This leads directly to the final result, making it less labor-intensive for the patient and eye care professional (ECP). The simultaneous compensation of the dimensions makes each answer from the patient more relevant. The effect of each change is immediately taken into account; therefore the patient and ECP can make an informed decision.

TRADITIONAL REFRACTION: 4 STEPS REQUIRED

Traditionally, ECPs achieve the result by bracketing the sphere, cylinder and axis individually, even though these three dimensions affect one another. This requires the rechecking of the values by repeating the process to give an accurate result. The ECP also has to compensate for the sphere and then estimate the final result.

A POWERFUL OPTICAL MODULE

The Vision-R 700 refraction system incorporates an exclusive breakthrough optical module. It allows for much smaller incremental power changes, making the switch significantly smoother for the patient. This liquid lens module is controlled by digital micromotors and provides:

  • A wider field of vision
  • Continuous power
  • Simultaneous changes
  • Silent lens changes
  • Instant power
  • Algorithms

Vision-R 700 Brochure
Vision-R 700 eFlyer
Vision-R 700 One-Pager
<p>It does not lessen the value of the OD. It does; however, create an environment where efficiency and repeatability are much easier to accomplish. It also aids in uniformity with multiple doctors.</p>
<p>Yes; however, it adjusts sphere, cylinder, and axis simultaneously, and it takes every answer into consideration, including “the same” or “I don’t know.”</p>
<p>Sphere power of +/- 20 diopters and cylinder power to 8 diopters</p>
<p>Yes, there is a full Manual mode.</p>
<p>Yes, there is the pre-programmed Smart Test and three slots are available for custom programming.</p>
General Overview